POTŘEBNÝ HARDWARE PRO VÝSTAVBU A SERVIS OPTICKÝCH LINEK
Architektura bezpečných optických sítí pro přenos přesného času
Jiří Štefl , CEO
24. dubna, 2018
• Passive layer
– Cables, duscts, cable closures, racks, ODFs
– Optical connectors, patchcords
– Splitters, WDMs (WDM, CWDM. DWDM)
• Active – transmission layer
– Transponder cards
– 100M – 2.7G
– 10G
– 100G
– SFP 100M – 10G, 40G ,100G transceivers overview
– EDFA amplifiers
– ROADM, reconfigurable MUX/DEMUX
Optical networks
Single fiber connectors (+adaptors)
• Standard: FC, SC, E2000, …,
• SFF (Small Form Factor): LC, MU, LX5, …,
• IP67 connector
Multifiber Connectors• Multi single connectors (fan-out)
• Ribbon MTP/MPO connectors
Non physical contact connectors• HMA connectors
Fiber optic connectors overview
Factory terminated – polished connectors
• All types of connectors terminated with wide range of fibers0.9 mm and cables 1.5 – 3.0 mm
Field terminated connectors
• Prepolished ferrule with piece of fiber – mechanicalconnection / crimping with cleaved fiber cable
• Prepolished ferrule with piece of fiber – fusion splicing withcleaved fiber cable, splice hidden in connector body
Fiber optic connectors technology
European Committee responsible for Electrotechnical StandardizationFounded in 1973, headquartes in Brussels, currently 30 members, OPTOKON is member of preparation standards comittee for European norms „EN“, specifications „ES“ and other related documents.
OPTOKON technical specs comply with EN...
International Electrotechnical Commission
Int. Standards organization deals with electrical, electronic and related technologies, cretaes International norms and specifications IECFounded in 1900, headquarets in Geneve
Over 60 members
Until 1997 known as Bell Communications Research, Inc. ( Bellcore)
Telecommunications research and development company created in 1984, headquartes in New JerseyMain business – OSS, Intelligent network, research, consulting&testing services
International Standards
The Telecommunications Industry Association (TIA) is the leading trade
association representing the global information and communications technology (ICT) industry through standards development, policy initiatives, business opportunities, market intelligence and networking events. TIA enhances the business environment for companies involved in telecom, broadband, mobile wireless, information technology, networks, cable, satellite, unified communications, emergency communications and the greening of technology. TIA is accredited by ANSI.
Specifications: PC APC
• Radius of ferrule (mm) 10-25 5-15
• Fiber height (nm) -70 to +50 -70 to +50
(undercut, protrusion)
• Offset (apex) (µm) < 50 < 50
• Angle 0° 8 (9)°
fiber height
offset
radius
angle Offset (apex) - the dome eccentricity
is defined as a distance between the
ferrule centre and the vertex of the
spherically polished endface relative
In case of APC - to the angled PC
reference plane
Ferrule end face geometry
Interferometer measurement
Non contact measurement of ferrule end face geometrical parameters
Standard Patchcords(2.5 mm diameter of ferrule)
FC patchcord
• Threaded body - pull proof, designed for use in high-vibration environments
• Commonly used with singlemode and polarization-maintaining optical fiber
• FC have been replaced in many applications by SC and LC connectors
• Used in measurement equipment, and SM lasers
• Standardized: TIA fiber optic connector intermateability standard EIA/TIA-604-4
CENELEC – EN 50377-2 FC connector family
• FC adapters:
– D hole
– DD hole
– Flange mount:
• Oval
• Square
• SC - Standard Connector, Subscriber Connector
• Standardized: TIA: SC is specified by the as FOCIS-3
CENELEC – EN 50377- 4 SC connector family
• Push-pull latching mechanism similar to common audio and video cables.
• Duplex SC connectors for bi-directional transmission
• Available SM, MM
• Pre-radiused ceramic ferrules configured for PC, Ultra, and APC polishing
• Adaptors: SC footprint standard
– Flange
– Flangeless
– Single – duplex version
– Plastic or metal mounting clip
– Screw mount18.0 0.1+
13.1 + 0.5/-0
9.5 + 0.5/-0
2.4 + 0.2/-0
RECOMMENDEDPANEL CUT OUT
Thickness 1,6 0.1+
SC patchcord
SC footprint Duplex adaptor
• Integrated protective cap protects ferrule from dust and rules out any laser light emissions
• Integrated spring for a guaranteed closing of the protective cap • Single mode and multimode versions available, PC and APC polishing• Full ceramic ferrule • Special ferrule preform for short polishing time • Adjustable in 60° steps • Excelent for high packing density • Colour and mechanical coding• Premium class 1 suiteable for high power systems
LSH (E2000) patchcord
SFF - Small Form Factor Connectors
half size 1.25 mm ferrulehigher density of connection
Duplex uniboot connector
• Adjustable pitch 6.25 vs 5.25 mm
• Reversible polarity
• Quick release latch
• 1.25 mm ferrule, one-half the size of current standard connectors• Increases panel density – provides duplex connection in 50% less space• Abbrev.: Lucent Connector, Little Connector, or Local Connector• Standardization: CENELEC EN 50377- 7 LC connector family• Available in SM, MM versions with Ultra and Angle (APC) polishing• User-friendly audible latch to indicate proper mating• Simplex and duplex version available• Pull – proof Ø 1.7 mm simplex mini-cord, • 1.8 x 3.5 mm duplex minizip cable or duplex dualan mini cable Ø 2.9 mm
Duplex adaptor fits standard SC footprint
LC patchcord
MPO (MTP) Connector Ribbon• 12/24 fibers
• Available SM (angled) and MM (flat) performance
• Push-on / Pull-off latching connector
• Easy connection and disconnection
• No need for matching material
• Fiber protrusion
• Low Insertion loss & Reflection
• Simple & Low cost
• IEC61754-7, TIA/EIA 604-5
Polyprophylene sulfid ferrule
Content
Fiber network (passive physical layer) includes:
• Rack cabinets / installed:
•outdoor – street cabinets
•indoor – rack cabinets in telehouses
• ODF – optical distribution frames / installed in Racks
• Wall/pole mount ODB (optical distribution boxes)
• CPE – customer premises equipment: end user boxes
• Optical closures / installed in manholes
RackRack is a standardized system for transparentinstallation and connection of various electrical andelectronic devices together with termination ofcable distribution in columns one above the otherin a steel frame.
Two standards:
19“ETSI
dimensions in inches metric units (mm)
most usualtelecoms
Main parameter – Height in number of units
wall mount Rack
stand alone Rack
• Rack Mount
• Wall mount
• End user boxes
• Outdoor
• 19" Racks
• Accessories
• Cable Closures
Cable Management System... managing optical cables with OPTOKON is EASY!
Cable Management System... managing optical cables with OPTOKON is EASY!
SSL (Stainless Steel Look) Technology
Optical closuresOptical closures are usually places in manholes. It creates junction point between opticalcables. Optical closure are waterproof sealed, contains cable holders and splice cassetteswith fiber splice protections. splice trays
INLINE (KSHT series) DOME (KSDT series)
Various types forvarious capacity offiber coresavailable
• European fiber optic cablemanufacturer
• Very latest moderntechnology
OPTOKON KABLE DESIGN & PRODUCTION CENTER
- FBT (Fused Biconic Taper) technology
(meet Bellcore requirements ANSI/NCSL Z540-1 and CENELEC norms)
- PLC (Planar couplers)
Couplers, WDM,CWDM, DWDM
DWDM available in a varietyof packaging options forstandard configurations of 4,8, 16, 32 and 40 channels.
DWDM system
DWDM mux/demux, 40 channels in C-band, 100 GHz spacing ITU-T grid
• Duplex – bi-di transmission
• SFP 100M – 10G transceivers overview
• EDFA amplifiers
• ROADM, reconfigurable MUX/DEMUX
Transmission systems
10/100/1G/10G/40G/100G
What is a transceiver ?
A transceiver is a device comprising both a transmitter and a receiver which are combined and share
common circuitry or a single housing.
Optical transceivers
Gigabit Interface Converters: S125-D55-LP-LX-(DD)
Features:
• Multimode VCSEL laser 850 nm
• Singlemode FP laser 1310 nm
• Singlemode DFB laser 1550 nm
• CWDM, DWDM wavelengths
• FO interface
duplex or single (Bi-Di) port options
• SX distance 550 m
• LX 20 km
• HX 40 km
• ZX 80 km
• UX 120 km
• EZX 160 km
SFP Series 1G Transceivers
• designed for use in service provider networks as L2access switches
• designed to be used in service provider networks asaggregation layer switches or in the data centers asTop-of-Rack transport switches
Access & Aggregation Switches
Previous version
Current version
EDFA development
• 2U chassis
• Optical ports and signalization – front panel
• 2x power supply (AC or DC)
• PC board – remote control (LAN - RJ45)
• 1U chassis
• All ports – FO, LAN (remote control) and signalization – at front panel
• 2x power supply (AC or DC)
• Up to 4 EDFA modules
JOSSS-100Intrusion detection in large perimeters
Large perimeter protection - e.g. state borders, airport areas, military bases, drinking water sources, railroads, highways, pipelines, etc.
Detection of failure and sabotage on long lines:- gas and oil pipelines, EHV lines, railroads, highways.
Monitoring the movement of vehicles along the sensor cable - e.g. determining the position of a train in real time.
Unusual situation detection - events such as an emergency brake being used on a train, accident on the highway, detection of traffic jams.
OPTOKON JOSSS-100 is a technology based onanalyzing signals in a fiber optic cable, whichchanges characteristics based on the vibration in itsarea. One segment of this technology is capable ofdetecting noise and vibration at distances of up to100 km.
OPTOKON Test Equipment
The PM-212 MPO cuts larger power meters to
ribbons
• Pocket Power Meter, Ribbon Pocket Power Meter
• Standard Power Meter and Light Source
• FTTx Power Meter and Light Source
• Loss Test Sets, 4 channel IL/RL tester
• POF Lost Test Set and POF Indicator
• Ruggedized Power Meter and Loss Test Set
• Mini OTDR Singlemode & Multimode version
• CWDM Optical Analyzer
• Precise laboratory Light source
THE SMALLESTIN THE MARKET
PM-215-GLPocket optical power meterUSB probe
Calibration Laboratory
• Independent
• Calibration of Fiber Optic Test Equipment from all manufacturers
Professional personnel certified by third party
• Traceability of etalons
• Interlaboratory Comparisons
• Accredited Calibration of OTDR’s
ACCREDITATION NUMBER 317/2011according to EN ISO/IEC 17025:2005
Calibration Center for Europe and the Asia-Pacific Market
• Service of Fiber Optic Test Equipment & Devices
• Calibration Laboratory
• Installation of Fiber Optics Lines
OPTOKON Service and Installation
SUMMARY
OPTOKON offers full portfolio for installation
• passive optical network layer
• active optical network layer
EU made products
ISO certified company
OPTOKON accredited Calibration Laboratory
tel. +420 564 040 111
fax +420 564 040 134
WWW.OPTOKON.COM
Thank You
For Your attention