Description:
Soluprep from Design Scientific (an entity of Resolution Systems)The Soluprep II solution preparation system automatically calculates and dispenses the exact amount of solvent required to prepare aprecise concentration based on the approximate mass of solute added by the operator.(ds-0307sp1)
2
(616) 392 - 8001 • (800) 572 - 6653 • Fax: (616) 396 - 7520 • 590 East 32nd Street, Holland, MI 49423 • [email protected] www.resolutionsys.com The Soluprep II solution preparation system automatically calculates and dispenses the exact amount of solvent required to prepare a precise concentration based on the approximate mass of solute added by the operator. The demand for greater accuracy from analytical instruments has prompted the automating of sample preparation based on the much more accurate solvent weight-to-sample weight basis. The Soluprep II accomplishes this by automatically preparing samples for liquid chromatography, gas chromatography, spectroscopy, viscosity, NMR and other analyses. The Soluprep II System improves laboratory sample-solution preparation by offering the following advantages. Sample solutions can be routinely prepared on a weight-to- weight, Normal, Molal or Molar basis to an accuracy of 0.02%, two parts in 10,000). Time is saved because only the approximate amount of the sample needs to be added to the sample. The computer com- pensates by adding the exact amount of solvent. Typical solution preparation time is less than 2 minutes. If your lab analyzes 50-100 samples per day the labor savings can rapidly recover the cost of investment. Up to eight different solvents can be dispensed with zero cross contamination. Ordinary, disposable sample bottles can be used to prepare the solution directly. The expense and labor of using volumetric glassware is eliminated. Eliminates cleaning and breakage of expensive volumetric glassware. Eliminates operator-to-operator variability. Provides ISO and GLP documentation. Decreases exposure to solvents. Samples solutions can be easily prepared with mixtures of solvents. This eliminates the labor and waste associated with premixing solvents. A self-adhesive label(s) for the prepared solution is automatically printed for each sample. A permanent file of each sample and its preparation is stored for later recall. Virtually any solvent can be used. Solution Preparation System Change in solvent density as temperature increases by 5º C. Solvent % Decrease Acetone 0.758 Acetic Acid 0.510 Methanol 0.827 Ethanol 0.825 n-Propanol 0.503 Methyl Ethyl Ketone 0.658 Toluene 0.616 Benzene 0.687 Carbon Tetrachloride 0.401 Chloroform 0.422 Methylene Chloride 0.513 Water 0.116 Cyclohexane 0.706 Dimethyl Sulfoxide 0.497 TABLE 1
Transcript
Page 1: SoluPrep

(616) 392 - 8001 • (800) 572 - 6653 • Fax: (616) 396 - 7520 • 590 East 32nd Street, Holland, MI 49423 • [email protected]

www.resolutionsys.com

The Soluprep II solution preparation system automatically calculates and dispenses the exact amount of solvent required to prepare a precise concentration based on the approximate mass of solute added by the operator.

The demand for greater accuracy from analytical instruments has prompted the automating of sample preparation based on the much more accurate solvent weight-to-sample weight basis. The Soluprep II accomplishes this by automatically preparing samples for liquid chromatography, gas chromatography, spectroscopy, viscosity, NMR and other analyses. The Soluprep II System improves laboratory sample-solution preparation by offering the following advantages.

Sample solutions can be routinely prepared on a weight-to-•weight, Normal, Molal or Molar basis to an accuracy of 0.02%, two parts in 10,000).Time is saved because only the approximate amount of the •sample needs to be added to the sample. The computer com-pensates by adding the exact amount of solvent.Typical solution preparation time is less than 2 minutes. If your lab •analyzes 50-100 samples per day the labor savings can rapidly recover the cost of investment.Up to eight different solvents can be dispensed with zero cross •contamination.Ordinary, disposable sample bottles can be used to prepare •the solution directly. The expense and labor of using volumetric glassware is eliminated. Eliminates cleaning and breakage of expensive volumetric glassware.Eliminates operator-to-operator variability.•Provides ISO and GLP documentation.•Decreases exposure to solvents.•Samples solutions can be easily prepared with mixtures of •solvents. This eliminates the labor and waste associated with premixing solvents.A self-adhesive label(s) for the prepared solution is automatically •printedforeachsample.Apermanentfileofeachsampleandits preparation is stored for later recall.Virtually any solvent can be used.•

Solution Preparation System

Change in solvent density as

temperature increases by 5º C.

Solvent % Decrease

Acetone 0.758

Acetic Acid 0.510

Methanol 0.827

Ethanol 0.825

n-Propanol 0.503

Methyl Ethyl Ketone 0.658

Toluene 0.616

Benzene 0.687

Carbon Tetrachloride 0.401

Chloroform 0.422

Methylene Chloride 0.513

Water 0.116

Cyclohexane 0.706

Dimethyl Sulfoxide 0.497

TABLE 1

Page 2: SoluPrep

Solution Preparation

Typical solution accuracy +/- 2 drops (one drop is approximately .03g)Number of methods stored 100

Number of solvent pumps From one to eight

Pump type Pulseless, self-priming, magnetically coupled, gear pumps. No rotating seals.

Wetted materials of constructionTeflon©,316stainlesssteel,graphite

Solvent delivery rate 100 ml/min

Electronic balances used Sartorius balance with 220g capacityMinimum computer required PC with Microsoft Windows, one COM Port, two USB ports

Electrical 110-240 Volts @ 50-60 Hz, 100 Watts.

Physical 27 cm (10.75”) wide X 42 cm (16.5”) long X 9.2 cm (3.625”) high

Connections USB, RS-232., RJ-12

Ordering InformationThe SoluPrep consists of a pump drive module having from one to eight pumps installed (please specify the number of pumps), the SoluPrep Operating Program, interface cables, power cord and instruction manual. We recommended that each pump used in a system be dedicated to pumping a single solvent.

SoluPrep Specifications


Recommended